Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 55 Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 70 Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 83 Deprecated: Required parameter $mode follows optional parameter $filterSapID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/settings_output.class.php on line 1735 Deprecated: Required parameter $type follows optional parameter $addType in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_categories.class.php on line 397 Deprecated: Required parameter $objAddonType follows optional parameter $selectedCatID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_categories.class.php on line 645 Deprecated: Required parameter $fontsKey follows optional parameter $isReturnCss in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_params_processor.class.php on line 166 Deprecated: Required parameter $type follows optional parameter $publishedCatOnly in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_addons.class.php on line 337 Deprecated: Required parameter $objTypeName follows optional parameter $catID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_addons.class.php on line 405 Deprecated: Required parameter $templateType follows optional parameter $templateID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_helper.class.php on line 871 Deprecated: Required parameter $objAddonsType follows optional parameter $numAddonsOnly in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_web_api.class.php on line 719 Deprecated: Required parameter $addontype follows optional parameter $addon in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/layouts/unitecreator_layout.class.php on line 519 Deprecated: Required parameter $containerID follows optional parameter $arrStylesAddons in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/layouts/unitecreator_layout_output.class.php on line 936
FIRE DAMPER: MULTI BLADE EXHAUST FIRE DAMPERS FOR MULTI-ZONE VENTILATION
DESCRIPTION
SPECIFICATIONS
DOWNLOAD

Model, WIP/V and WIP PRO/V, cut-off dampers are designed for installation in automatically-activated fire ventilation systems. They support single fire zones, as well as several zones within a single facility. They prevent propagation of fire, smoke and fire gases to the neighbouring zones. The dampers can operate in so-called mixed systems (/V-M variant).

 

Features

  • Small thickness of damper - 135 mm (model WIP PRO/V) and 140 mm (model WIP/V)
  • Cut-off barrier does not protrude outside the damper body, regardless of damper dimensions
  • Possible installation in a partition, on a duct ended with a duct cover
  • Optional making of dampers with penetrations for rounded ducts
  • Operating reliability up to 10000 cycles

WIP/V DIMENSIONS

 

NOMINAL WIDTH 120-1000 mm
NOMINAL HEIGHT 160-1000 mm
MAXIMUM AREA OF SECTION OF SINGLE DAMPER Not larger than 1m²

 

WIP PRO/V DIMENSIONS

 

NOMINAL WIDTH 110-900 mm
NOMINAL HEIGHT 263-1250 mm
MAXIMUM AREA OF SECTION OF SINGLE DAMPER Not larger than 1.125m²

 

 

WIP/V CONTROLS

 

BELIMO TYOPE MECHANISM Actuators family without return spring, without thermoelectric trigger (BE, BLE series)

 

WIP PRO/V CONTROLS

 

BELIMO TYOPE MECHANISM Actuators family without return spring, without thermoelectric trigger (BE, BLE series)

 

OPERATION AND MAINTENANCE MANUAL (WIP/V AND WIP/V-M)

View the Operation and maintenance manual for the multi-blade smoke exhaust fire damper for multi-zone fire ventilation, model WIP/V and WIP/V-M (Opens in new browser tab).

TECHNICAL CATALOGUE (WIP/V AND WIP/V-M)

View the technical catalogue for the multi-blade smoke exhaust fire dampers for multi-zone fire ventilation, model WIP/V and WIP/V-M (Opens in new browser tab).

OPERATION AND MAINTENANCE MANUAL (WIP PRO/V & WIP PRO/V-M)

View the Operation and maintenance manual for the multi-blade smoke exhaust fire damper for multi-zone fire ventilation, model WIP PRO/V and WIP PRO/V-M (Opens in new browser tab).

TECHNICAL CATALOGUE (WIP PRO/V AND WIP PRO/V-M)

View the technical catalogue for the smoke exhaust fire damper for multi-zone fire ventilation, model WIP PRO/V and WIP PRO/V-M (Opens in new browser tab).

 