Fire dampers for material transport - Safevent
FIRE DAMPERS FOR MATERIAL TRANSPORT
DESCRIPTION
SPECIFICATIONS
MANUAL

Fire Dampers for materiale transport

Our fire dampers for materiale transport prevents the spread of transported burning materiale to your production’s adjacent fire compartments. During normal operation, the material is transported 100 % unrestricted through the fire damper’s passageway. In case of danger, smoke detectors, temperature switches and other sensors will send a signal to the operating unit. Inside the operating unit, the power circuit to the engine is interrupted and the built-in spring return actuator will currentlessly close the fire damper. Depending on its size, the damper is able to close in 5 to 10 seconds. In the event of a power failure, the damper closes.

 

 

Furthermore, our fire dampers for material transport can be connected to other and existing controls and fire alarm systems.

 

APPLICATION

Our fire dampers for material transport may be installed in both horisontal as well as vertical masonry or concrete components i.e. walls, above the ceiling and below the ceiling. Here it can be connected to systems such as:

  • Pneumatic conveyors
  • Pneumatic dispatch
  • Pneumatic dispatch
  • Garbage chute systems
  • Downpipes
  • Ventilation systems with aggressive media
  • Dust extraction units
  • Inspection ports
  • Transformer rooms
  • Industrial ventilation
  • Smoke control

 

MATERIAL TYPES

Our fire dampers for material transport may be used to convey several flammable mediums - both solids, liquids and gaseous. Additionally, we offer a costumised inset for transportation of small-grained material such as seeds, grain and flour.

SPECIFICATIONS: R90 FIRE DAMPER FOR MATERIAL TRANSPORT

DIBt AUTHORISATION NUMBER z-19-17.1180
FIRE REISTANCE DURATION 90 minutes (certified according to DIN 4102 part 111)
TUBE DIAMETER NW 100 - 630 mm
PERMITTED COMPONENTS MASONRY: 115 mm
CONCRETE: 100 mm
TYPES OF INSTALLATION - Wall mounting
- Above ceiling
- Below ceiling
MATERIAL Sheet steel St37
HEIGHT 615 to 1370 mm (depending on size)
WIDTH 570 to 1040 mm (depending on size)
DEPTH 200 to 300 mm (depending on size)
WEIGHT 75 to 350 kg (depending on size)
SOCKET LENGTH FRONT: 250 mm
BACK (FACING WALL/CEILING): 500 mm
CLOSING PROCEDURE Spring force
OPENING PROCEDURE Electric engine
NUMBER OF ENGINES 1 to 2 (depending on size)
SPRING RETURN ACTUATOR 24 volt
TRIGGERING MECHANISM Smoke detector or temperature indicator

ASSEMBLY AND MAINTENANCE MANUAL

View or download the assembly and maintenance manual for fire dampers for material transport, FIRE SAFE R90.

QUICKGUIDE

View or download the quickguide to the fire damper for material transport, FIRE SAFE R90.

Have any questions related to this product or do you simply wish to receive a quotation? Then click on one of the two icons below to contact us by either mail or phone. Your inquiry pleases us and is always welcomed.
sales@safevent.dk

WRITE US

+45 88 63 89 00

CALL US

We use cookies to create a better user experience for you, adjust our content and gather statistics of traffic. If you keep browsing this website, we assume that your agree to recieve cookies from www.safevent.dk.