Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 55 Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 70 Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 83 Deprecated: Required parameter $mode follows optional parameter $filterSapID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/settings_output.class.php on line 1735 Deprecated: Required parameter $type follows optional parameter $addType in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_categories.class.php on line 397 Deprecated: Required parameter $objAddonType follows optional parameter $selectedCatID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_categories.class.php on line 645 Deprecated: Required parameter $fontsKey follows optional parameter $isReturnCss in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_params_processor.class.php on line 166 Deprecated: Required parameter $type follows optional parameter $publishedCatOnly in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_addons.class.php on line 337 Deprecated: Required parameter $objTypeName follows optional parameter $catID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_addons.class.php on line 405 Deprecated: Required parameter $templateType follows optional parameter $templateID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_helper.class.php on line 871 Deprecated: Required parameter $objAddonsType follows optional parameter $numAddonsOnly in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_web_api.class.php on line 719 Deprecated: Required parameter $addontype follows optional parameter $addon in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/layouts/unitecreator_layout.class.php on line 519 Deprecated: Required parameter $containerID follows optional parameter $arrStylesAddons in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/layouts/unitecreator_layout_output.class.php on line 936
DUST EXPLOSION TESTING
Knowing every detail of your generated dust's explosive characteristics is a key factor in deciding which explosion protection equipment that will best safekeep your machinery, employees and plants.
Lots of data regarding the explosive properties of different materials are already freely available. However, this data is only indicative, as there is a huge difference between dust originating from the same type of material because of its size and how the the grains are put together.
Relying solely on the freely available data could cause you to either pay too much for a explosion protection solution or - in an even worse scenario – end up with inadequate equipment.
For these reasons we are offering tests that determine whether your dust is explosive and – if the dust is explosive – how the explosion will behave.
The most important values to test and determine are:
Kst - the speed of the explosion’s development
Pmax - the maximum amount of pressure that the material is able to produce.
Basic testing

€1,900.00

  • Kst testing
  • Pmax testing
Write us
OTHER TESTS
Other tests regarding ignition of the material can be conducted at your request. These include:
- Flammability classification
- Train Firing
- Thermal Decomposition Screen
- Isothermal basket test (50/100/150mm)
- UN 4.2 Classification
- Minimum Ignition Temperature (MIT)
- 5mm Layer Ignition Temperature (LIT)
- Minimum Ignition Energy (MIE)
- Explosion Indices Screen (Kst, Pmax)
- Explosion Indices Series (Kst, Pmax)
- Minimum Explosible Concentration (MEC)
- Limiting Oxygen Concentration (LOC)
- Powder Resistivity
- Flashpoints
- Sustained combustibility
- Flammability limits in air
- Flammability diagrams in air
THE PROCESS
SEND SAMPLE
You send a sample of the materiale you want tested
ANALYSIS
We are having the sample analysed
TEST RESULTS
You receive the test results
You may expect this process to take between 2-5 weeks depending on which tests you want carried out.
Typical sample size: 1-3 kg