Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 55 Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 70 Deprecated: Required parameter $sanitizeType follows optional parameter $initVar in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/functions.class.php on line 83 Deprecated: Required parameter $mode follows optional parameter $filterSapID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/framework/settings_output.class.php on line 1735 Deprecated: Required parameter $type follows optional parameter $addType in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_categories.class.php on line 397 Deprecated: Required parameter $objAddonType follows optional parameter $selectedCatID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_categories.class.php on line 645 Deprecated: Required parameter $fontsKey follows optional parameter $isReturnCss in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_params_processor.class.php on line 166 Deprecated: Required parameter $type follows optional parameter $publishedCatOnly in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_addons.class.php on line 337 Deprecated: Required parameter $objTypeName follows optional parameter $catID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_addons.class.php on line 405 Deprecated: Required parameter $templateType follows optional parameter $templateID in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_helper.class.php on line 871 Deprecated: Required parameter $objAddonsType follows optional parameter $numAddonsOnly in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/unitecreator_web_api.class.php on line 719 Deprecated: Required parameter $addontype follows optional parameter $addon in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/layouts/unitecreator_layout.class.php on line 519 Deprecated: Required parameter $containerID follows optional parameter $arrStylesAddons in /customers/6/5/5/safevent.dk/httpd.www/administrator/components/com_blox/inc_php/layouts/unitecreator_layout_output.class.php on line 936
sample74
ASPIRATING SMOKE DETECTOR - FAAST LT
Realiable. Large area of coverage. Easy maintenance
FAAST LT: ASPIRATING SMOKE DETECTION SYSTEM
DESCRIPTION
SPECIFICATIONS
MANUAL

FAAST LT is our aspirating smoke detector of choice, when it comes to detection of smoke particles. Perforated tubes installed along the ceiling, continually leads air from everywhere around the room to be analysed by the aspirating smoke detectors. This allows few smoke detectors to cover a large area.


The aspirating smoke detector is serviced directly at the detector, that can be installed in an easily accessible position. Compressed air is blown through the tubes, to secure that the air can pass through the holes unhindered.


Air is sucked into the aspirating smoke detector. There it is analysed by laser detectors, that is designed to register smoke particles. If smoke particles are registered by the laser the detector, an alarm is triggered. The alarm can be connected to existing communications systems.


The FAAST LT is well suited for larger areas or areas that require fast and reliable detection of smoke such as containing vital electronics or servers.


The aspirating smoke detector can be mounted in areas with a high ceiling, in which service of conventional smoke detectors would otherwise be difficult and costly. The FAAST LT eliminates these difficulties as only the perforated tubes need to be mounted below ceiling. This allows the FAAST LT to be installed in normal working height.

SPECIFICATIONS: FAAST LT ASPIRATING SMOKE DETECTION SYSTEM

 

DIMENSIONS Height: 40.3 cm
Width: 35.6 cm
Depth: 13.5 cm
MAXIMUM SINGLE PIPE LENGTH 100 m
MAXIMUM BRANCHED PIPE LENGTH 160 m (per channel)
MAXIMUM AIR INLET HOLES 18 per channel
COVERAGE AREA Up to 2000 m²
SENSITIVITY Up to 0.07 % obs/m
SOUNDER OUTLET 1 per channel
INTERFACES TERMINAL BLOCKS Power supply, relays, sounder outputs
EXTERNAL INPUT USB-port, buttons (test, reset, disable)
USB STANDARD USB-cable for type B USB connection
FILTRATION Replaceable speeds
FAN CONTROL 10 programmable speeds
SMOKE DETECTORS Optical laser point type
EXTERNAL SUPPLY VOLTAGE 18.5-31.5 V
REMOTE RESET TIME 2 s
POWER RESET 0.5 s
1 CHANNEL DEVICE AVG. OPERATING CURRENT 170 mA @ 24 VDC (excluding sounders)
2 CHANNEL DEVICE AVG. OPERATING CURRENT 270 mA @ 24 VDC (excluding sounders)
1 CHANNEL MAX OPERATING CURRENT 360 mA @ 24 VDC (excluding sounders)
2 CHANNEL MAX OPERATING CURRENT 570 mA @ 24 VDC (excluding souders)
RELAY CONTACT RATINGS 2.0 A @ 30 VDC, 05 A @ 30 VAC
OPERATING TEMPERATURE -10°C to 55°C
HUMIDITY RANGE 10 % to 93 % (non condensed)
IP RATING 65

SETUP AND CONTROL GUIDE

View or download the setup and control guide for the aspirating smoke detector, FAAST LT.

Have any questions related to this product or do you simply wish to receive a quotation? Then click on one of the two icons below to contact us by either mail or phone. Your inquiry pleases us and is always welcomed.